Difference between revisions of "Turnigy SK4250-650"

From ItsQv
Jump to: navigation, search
(Created page with "<i>July 2008</i><br> Testing!<br><br> '''Drive System Information and Test Results'''<br> Catalog Information<br>[http://www.hobbyci...")
 
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
<i>July 2008</i><br>
+
[[File:BTI.png|link=Power_Systems_&_Testing|Testing!]]<br>
[[File:BTI.png|link=Motor_Testing_Index|Testing!]]<br><br>
+
<i>July 2008</i><br><br>
  
 
'''Drive System Information and Test Results'''<br>
 
'''Drive System Information and Test Results'''<br>
Catalog Information<br>[http://www.hobbycity.com Supplier Site]  
+
Catalogue Information<br>[http://www.hobbycity.com Supplier Site]  
  
 
[[File:SK4250-cat.png|center]]<br>  
 
[[File:SK4250-cat.png|center]]<br>  
Line 9: Line 9:
 
=== <br>Test Results  ===
 
=== <br>Test Results  ===
  
Test results are done "On the bench" using the Medusa Research Power Analyzer Pro data aquisition module with a bench mounted test stand. Run times vary depending on the power range and motor type. Data sampling either follows a ramp up to full (100%) power or a step and hold function at 0, 25, 50, 75 &amp; 100% Throttle. System power is provided by a common flight battery pack and is used, without re-charge, for several tests. All summary results are "best case" average or stable at the given measure.  
+
Test results are done "On the bench" using the Medusa Research Power Analyser Pro data acquisition module with a bench mounted test stand. Run times vary depending on the power range and motor type. Data sampling either follows a ramp up to full (100%) power or a step and hold function at 0, 25, 50, 75 &amp; 100% Throttle. System power is provided by a common flight battery pack and is used, without re-charge, for several tests. All summary results are "best case" average or stable at the given measure.  
  
 
[[File:SK4250-data.png|center]]<br>  
 
[[File:SK4250-data.png|center]]<br>  
Line 17: Line 17:
 
=== '''Data Chart'''  ===
 
=== '''Data Chart'''  ===
  
Chart represents collected data on the 12 x 8 Turnigy Woop propellor.  
+
Chart represents collected data on the 12 x 8 Turnigy Woop propeller.  
  
 
[[File:SK4250 Chart.png|center]]<br>
 
[[File:SK4250 Chart.png|center]]<br>
  
 
[[Category:Motors]]
 
[[Category:Motors]]

Latest revision as of 16:26, 11 January 2016

Testing!
July 2008

Drive System Information and Test Results
Catalogue Information
Supplier Site

SK4250-cat.png


Test Results

Test results are done "On the bench" using the Medusa Research Power Analyser Pro data acquisition module with a bench mounted test stand. Run times vary depending on the power range and motor type. Data sampling either follows a ramp up to full (100%) power or a step and hold function at 0, 25, 50, 75 & 100% Throttle. System power is provided by a common flight battery pack and is used, without re-charge, for several tests. All summary results are "best case" average or stable at the given measure.

SK4250-data.png


Data Chart

Chart represents collected data on the 12 x 8 Turnigy Woop propeller.

SK4250 Chart.png